Product Application

Corridor Lighting

Pathway illumination during power outages. Our high-temperature batteries power emergency corridor lighting systems that guide occupants safely to exits in commercial, industrial, and public buildings.

Emergency Corridor Lighting

Safe Pathway Illumination

Emergency corridor lighting ensures safe evacuation by providing adequate illumination along escape routes during power failures. Our high-temperature battery packs are designed for bulkhead lights, downlights, and linear fixtures installed in corridors, stairwells, and passageways where ambient temperatures can be challenging.

1 lux
Min Floor Level (EU)
1 fc
Min Floor Level (US)
3 Hours
EU Duration
+70°C
Max Operating
US

US Market Standards

UL 924, NFPA 101 & IBC Compliance

US emergency corridor lighting must comply with UL 924, NFPA 101 Life Safety Code, and International Building Code (IBC). These standards ensure adequate illumination for safe egress during emergencies.

90-Minute Minimum Runtime

Battery backup must provide at least 90 minutes of illumination

1 Footcandle at Floor Level

Minimum illumination required along the path of egress

40:1 Maximum Uniformity Ratio

Ratio between maximum and minimum illumination levels

Stairway Requirements

10 footcandles required at stair treads during emergency

US Technical Specifications

StandardsUL 924, NFPA 101, IBC
Battery Runtime≥90 minutes
Floor Illumination≥1 footcandle (10.76 lux)
Stairway Illumination≥10 footcandles
Uniformity Ratio≤40:1 (max:min)
Fixture SpacingPer photometric design
Monthly Test30 seconds functional

EU Technical Specifications

StandardsEN 1838, EN 60598-2-22
Battery Runtime≥1 hour (3 hours typical)
Escape Route (center)≥1 lux
Escape Route (band)≥50% of center line
Uniformity Ratio≤40:1 (max:min)
Anti-Panic Area≥0.5 lux
Glare Limit (UGR)≤25 (below eye level)
EU

European Market Standards

EN 1838 & EN 60598-2-22 Compliance

European emergency escape route lighting is governed by EN 1838 (Lighting applications - Emergency lighting) and EN 60598-2-22 (Luminaires for emergency lighting). These standards define illumination levels, uniformity, and duration requirements.

1 Lux Minimum on Escape Routes

Center line of escape route up to 2m wide must have ≥1 lux

3-Hour Duration Standard

Most European countries require 3-hour emergency duration

Anti-Panic Lighting

Open areas >60m² require 0.5 lux minimum horizontal illumination

50% Output in 5 Seconds

Emergency lighting must reach 50% output within 5 seconds

Corridor Lighting Fixture Types

Our batteries power various emergency corridor lighting fixtures

Emergency Downlights

Recessed ceiling-mounted fixtures for modern corridors

Bulkhead Lights

Robust wall-mounted fixtures for stairwells and corridors

Linear Fixtures

Continuous lighting for long corridors and passageways

Twin Spot Heads

Adjustable emergency spotlights for targeted illumination

Recommended Battery Solutions

High-temperature batteries designed for corridor emergency lighting applications

High-TempEU 3hr

NiCd SC2000 Pack

Ideal for enclosed bulkhead and downlight fixtures

  • +70°C maximum operating temp
  • 3-hour runtime at +55°C
  • 4-year design life
RoHSUS 90min

NiMH AA2100 Pack

Eco-friendly option for standard temperature applications

  • +60°C maximum operating temp
  • Higher energy density
  • Cadmium-free, RoHS compliant
Long LifePremium

LiFePO4 Pack

Premium solution for reduced maintenance requirements

  • 2000+ cycle life
  • 6-8 year design life
  • Integrated BMS protection

Need Custom Corridor Lighting Battery Solutions?

Our engineering team can design custom battery packs to meet your specific corridor lighting requirements for both US and European markets.